SETTINGS |
1 |
TEMP.WATER |
Maximum water temperature. |
2 |
TEMP. EXHAUST |
Maximum exhaust temperature. |
|
3 |
TEMP. CIRCULATOR |
Water temperature that the circulator pump starts to operate. |
|
4 |
TEMP. BYPASS |
Water temperature that the bypass valve starts to operate. |
|
5 |
FAN AIR MAX |
Maximum power amount of the fan (%) in the full burning process. |
|
6 |
DT WATER |
Temperature difference below the maximum water temperature that the fan power starts to decrease. |
|
7 |
DT EXHAUST |
Temperature difference below the maximum exhaust temperature that the fan power starts to decrease. |
|
8 |
IGNITION AIR |
Power amount of the fan (%) in the ignition process. |
|
9 |
IGNITION TIME |
Maximum time of the process “ignition”. Fan power is determined only by the “ignition air” setting at this process. |
|
10 |
OFF TIME |
Time that exhaust temperature must be below the “11-Off exhaust” so that the controller is set into “end of fuel” process. |
|
11 |
OFF EXHAUST |
Exhaust temperature value that determines when the fuel has ended. |
|
12 |
CONS. PERIOD |
Repeating time of the process “flame conservation”. In this process the fan power works at “09-ignition air” so that the flame is conserved. |
|
13 |
CONS. DURATION |
Duration of the process “flame conservation”. |
|
14 |
MOTOR TYPE |
Choosing the type of the air motor. Automatically this option is “NORMAL” and for high speed motors change the value to “High Speed’’ |