espa banner

DM - CHL: Terminal Power Units 1kW DM-CHL

After a long market research in the field of dimmers and because of the continuous increase of professional stores demands, MASTER Electric & Electronic made a coordinated effort to design and manufacture an innovative, reliable and intelligent digital system.

Utilizing the latest technology, the company designed the unique control system of lighting and ventilation MULTIDIMMER 8 Channel.

The system was designed to fulfill the needs of professional stores in the basic areas of lighting and ventilation by providing smart solutions for management, indication, reliable and easy installation of electrical loads. The basic advantage of the system is the significant reduction of power consumption in a building.

The installation of MULTIDIMMER 8 Channel gives the user the advantage of controlling different sectors of a facility from one or more access points.

The use of the system is as simple as possible, so that users may control it without having to learn technical details or complicated procedures.

It can control up to 8 different sections of lighting or ventilation using the Central Control Unit (DM-8CHL) and as many Terminal Power Units (DM-CHL) the installation needs.

It can also control Terminal Units with output of 0-10V for electronic ballasts, LED controllers, etc.

For each channel we may use up to 4 Terminal Power Units (1kW each per unit), so each channel may control up to 4kW. The Terminal Power Units may be driven by any of the 3 phases, so that power distribution is similar at each phase.

The user can control each channel separately, or control all channels together, or use 3 different lighting scenarios (the user may change each scenario any time he wishes). The control is done by using the Central Control Unit (DM-8CHL) or from the Remote Control Unit (DM-LCD).

If the user wishes to control the system from another access point, he may connect another Remote Control Unit.

Technical Specifications

DM - 8CHL: Central control unit (8 channel)



OPERATING VOLTAGE: 180 - 230V AC
POWER LINE FREQUENCY: 50Hz
POWER CONSUMPTION: 10mA
ENVIRONMENT TEMPERATURE: -20ο C to +50ο C
WIRE SIZE: From 0,5mm to 3,5mm
MOUNTING: Din-rail mounting 35 x 7.5 mm (DIN 45277)
NUMBER OF TERMINALS TO CONTROL: Up to 24 terminal units in total, and up to 4 at each channel.
CONNECTION TO DM-LCD: Through a 4-wire telephone cable using RJ-11 plugs (up to 100 meters cable length)


DM - CHL: Terminal Power Units 1kW



OPERATING VOLTAGE: 180 - 230V AC
POWER LINE FREQUENCY: 50Hz
MAXIMUM OUTPUT POWER: 1000 Watt
CONTROL LOAD: Resistive & Halogen, Inductive transformers, Electronic transformers, Led, Electric single phase motors Universal and asynchronous with torque strongly depended from motor speed (centrifugal pumps, fans, ventilations etc)
ENVIRONMENT TEMPERATURE: -20ο C to +50ο C
FUSE: 6A/230V AC (for short-circuit protection)
WIRE SIZE: From 0,5mm to 3,5mm
MOUNTING: Din-rail mounting 35 x 7.5 mm (DIN 45277)


DM - CHL/1 - 10V: Terminal Units with 1-10V output



OPERATING VOLTAGE: 180 - 230V AC
POWER LINE FREQUENCY: 50Hz
NUMBER OF DEVICES TO CONTROL: Up to 50 devices.
CONTROL LOAD: Devices that use the standard control protocol 1-10V (dimmable electronic ballasts, LED Controllers etc)
ENVIRONMENT TEMPERATURE: -20ο C to +50ο C
FUSE: 6A/230V AC. (for short circuit protection)
WIRE SIZE: From 0,5mm to 3,5mm
MOUNTING: Din-rail mounting 35 x 7.5 mm (DIN 45277)


DM - LCD: Remote Control Unit



DISPLAY: Liquid Crystal Display (LCD)
POWER CONSUMPTION: 10mA
ENVIRONMENT TEMPERATURE: -20o C to +50o C
MOUNTING:Wall mount
CONNECTION TO DM-8CHL: Through a 4-wire telephone cable using RJ-11 plug (up to 100 meters cable length).

Draft of Electrical Installation

Single-phase installation example
 
Three-phase installation example
 
Installation example using dimmable ballasts with 1-10V

Product Description

A) DM-8CHL: Central control unit (8 channel) DM-8CHL contains:

1) 1 button (channel) for the selection of channel we want to regulate (1-8)
2) 2 buttons (up, down) for the increment or decrement of power in the selected channel (0% to 99%)
3) 3 buttons (memo 1. 2. 3.) for the generation and selection of 3 different lighting scenarios
4) 1 display (channel) indicating the selected channel
5) 1 display (power) indicating the power of the selected channel (0% to 99%)
6) 2 contacts for supply voltage N (neutral), L(line)
7) 8 contacts (1Ch, 2Ch,…,8Ch) for communication with the terminal power units.
8) 1 input for connection with the remote control unit (DM-LCD)

DM-CHL: TERMINAL POWER UNITS 1kW. DM-CHL contains:

1) 2 contacts for supply voltage N (neutral), L (line)
2) 1 contact ( ) for communicating with central control unit (DM-8CHL)
3) 1 power ()output for load
4) Fuse with sliding fuse holder for short circuit protection

DM-CHL/1-10V: 1-10V TERMINAL UNIT WITH 1-10V OUTPUT. DM-CHL/1-10V contains:

1) 2 contacts for supply voltage N (neutral), L (line)
2) 1 contact ( ) for communicating with central control unit (DM-8CHL)
3) 2 contacts (+ / - ) with 1-10V standard output protocol for communication with fluorescent electronic ballasts, LED controllers, etc.
4) Fuse with sliding fuse holder for short circuit protection

DM-LCD: REMOTE CONTROL UNITM-LCD. DM-LCD contains

1) 8 buttons for channel selection
2) 2 buttons (up, down) for regulating the level of the selected channel
3) 3 buttons (memo 1. 2. 3.) for the generation and selection of 3 different lighting scenarios
4) 1 button (ON/OFF) for activating and deactivating the system
5) Liquid crystal display (LCD) with backlight, graphic and numeral indication of all channels (1 Channel, 2 Channel, ... to 8 Channel)
6) 1 input for connection with central control unit (DM-8CHL)