espa banner

PELLET CONTROLLER (NEW) PWC - 2500

Biomass electronic controller PWC 2500 was designed to cover the needs of control and management of pellet burners, biomass stoves and wood stoves.

It is a safe and reliable product that was designed using the latest electronic components and integrated circuits, and was especially focusedf or use in very difficult working environments.

The software was designed tobe flexible for all kinds of burners and stoves, and it is continuously improvedfor even better, more economic and user-friendly use.

Technical Specifications

Controller PWC - 2500 for his control and installation has the following features:

  • LCD display  to display the settings and operating  data with English characters.
  • Led Indicators for direct and continuous flow of information  to inform user and technician.
  • BUTTON A1 - A2 - A3 - A4 for adjusting the desirable temperature of the water circuit, entering and leaving the MENU to configure the operating instructions and system activation-deactivation
  • Security 6A / 230VA protecting device and regional short-circuit systems.
  • Terminal for input of digital and analog sensors.
  • Terminal for output signal for controlling  of regional systems of the unit and the heating circuit.

Settings & Commands

Button A1-A2: They are used for increase or decrease of the boiler’s temperature
Button A3: For entering or exiting from the menu
(press for 3 sec)
Button A4: For the activation or deactivation of
the entire system


*After entering the menu, buttons A1 and A2 are
used for increasing and decreasing the values,
while buttons A3 and A4 are used to select which
value we want to change.
*The “User Menu” has access only on the basic settings
*The “Special Menu” has full access on all settings.
(pressButtons A3 and A4 continuouslyfor 5 sec)



USER: The “User Menu” has access only on the basic settings.

 

 

BASIC

SETTINGS

1

FUEL SELECTION

Selection of fuel and equivalent program  ( Biomass , Wood ,             Wood->Biomass)

2

WATER TEMPERAT.

Maximum water temperature in the boiler

3

FEEDER VALUE

Feeder fuel supply (%) in the process of "Full Burn"

4

AIR VALUE

Air supply (%)  from ventilator in the process of "Full Burn"

5

FEDER MANUAL

Semiautomatic command for manually supplying fuel

 

Special Menu: The “Special Menu” has full access on all settings.

 

BASIC

SETTINGS

1

FUEL SELECTION

Selection of fuel and equivalent program  ( Biomass , Wood ,             Wood->Biomass)

2

WATER TEMPERAT.

Maximum water temperature in the boiler

3

FEEDER VALUE

Feeder fuel supply (%) in the process of "Full Burn"

4

AIR VALUE

Air supply (%)  from ventilator in the process of "Full Burn"

5

FEEDER MANUAL

Semiautomatic command for manually supplying fuel

AUTO

IGNITION

6

1st CLEAN TIME

Time of fan operation to remove ashes from inside the burner before starting the "auto ignition" process

7

1st FEEDING TIME

Time of fan operation to remove ashes from inside the burner before starting the "auto ignition" process

8

AIR VALUE

Air supply (%) from ventilator in the process of "auto ignition"

9

MAX TIME

Maximum time for achieving  the "auto ignition" process before an alarm occures

FLAME

DETECTION

10

SELECTION

Selection of flame detection sensor                                                                    ( photosensor or exhaust temperature sensor )

11

MINIMUM VALUE

Minimum value that is considered valid for proceeding to the burn process

12

TIME ON

Time that the sensor value must be above the minimum value (On), so that the flame detection is considered valid

13

TIME OFF

Time that the sensor value must be below the minimum value (Off), so that the flame detection is considered invalid

INITIAL

BURN

14

FEEDER VALUE

Feeder fuel supply (%) in the process of "Initial Burn"

15

AIR VALUE

Air supply (%)  from ventilator in the process of "Initial Burn"

16

TIME

Time of the process "Initial Burn" before it passes to the "Full Burn"

REDUCED

BURN

17

FEEDER VALUE

Feeder fuel supply (%) in the process of "Reduced Burn"

18

AIR VALUE

Air supply (%) from ventilator in the process of "Reduced Burn"

19

DT WATER TEMPER.

Temperature difference below the Maximum Water Temperature that the process "Reduced Burn" is active

20

EXHAUST TEMPER.

Exhaust temperature that the process of "Reduced Burn" is active regardless of water temperature

21

FLAME CONSERVANT.

Exhaust temperature that the process of "Reduced Burn" is active regardless of water temperature

REPEATED

CLEAN

22

ACTIVATE

Activate or deactivate the "Repeated Clean" process (periodic air cleaning) during the combustion

23

TIME REPEAT

Time that the system repeats the "Repeated Clean" process

24

TIME FUCTION

Time that the  "Repeated Clean" process is active

25

AIR VALUE

Air supply (%) from ventilator in the process of "Repeated Clean"

WOOD

MODE

26

EXHAUST. TEMPMAX

Maximum exhaust temperature that the air supply is stopped completely

27

AIR VALUE MAX

Maximum air supply (%)  from ventilator in the process of "Wood Mode"

28

DT WATER TEMP

Temperature difference below the maximum water temperature that the "economy mode" is active

29

DT EXHAUST TEMP

Temperature difference below the maximum exhaust temperature that the "economy mode" is active

30

EXHAUST TEMP OFF

Exhaust temperature limit to detect "end of fuel" (automatically switches to biomass when "Wood->Biomass" mode is selected)

31

EXHAUST OFF TIME

Time that exhaust temperature must be below the limit so that the "end of fuel" is detected

OTHER

SETTINGS

32

WAIT BURN OUT

Time of fan operation after the "stop" command, so that the remains are burned out

33

DT RESTART

Difference of boiler water temperature that must be reached after burn out, so that burner can start again.

34

CIRCULATOR TEMP.

Circulator pump starting temperature

35

FEEDER PERIOD

The period of feeding (the actual amount of feeding fuel is not affected by this setting, only the frequency of "on" and "off")

36

FEEDER TEMP SENSOR

Activate or deactivate the feeder safety sensor which halts the feeding process in case of feeder overheating

37

SILO SENSOR

Activate or deactivate the silo sensor

38

DT COMPENSATION

Temperature difference that is substructed from maximum water temperature in case of external temp. thermostat

39

AIR MOTOR TYPE

Selection of the type of motor

40

AUXOUTPUT